Product Details:
Minimum Order Quantity | 1 Piece |
Frequency | 50/60 Hz |
Input Rated Voltage | 400 V |
Communication Software | Local View - Net Vision - Web Browser |
Output Rated Voltage | 220-415 V |
Online Mode Efficiency | Up to 95% |
ECO Mode Efficiency | Up to 98% |
Ambient Temperature | 0-40 Deg C (15 to 25 Deg C for maximum battery life) |
Relative Humidity | 0-95 % non-condensing |
Maximum Altitude | 1000 m without derating |
Interfaces | RS232 - Ethernet |
Optional cards | SNMP card - ADC/RS485 card - MODBUS card |
Advantages Innovative Design:
Sn [kVA] | 10 | 15 | 20 |
Pn [kW] | 9 | 13.5 | 18 |
Input / output | 3/1 - 3/3 | 3/3 |
Input |
|
---|---|
Voltage tolerance | ± 20 % (-40 % @ 70 % of nominal load) |
Power factor / THDI | 0.99 / < 2.5% |
Output |
|
---|---|
Voltage tolerance | ± 1% |
Rated frequency | 50/60 Hz ±2 (up to ±5 with generator - selectable) |
Overload | up to 150 % for 30 seconds |
Crest factor | 3:1 (complying with IEC 62040-3) |
Connections | terminals |
Bypass |
|
---|---|
Rated voltage | rated output voltage |
Voltage tolerance | ±15 % (± 20 % with generator - selectable) |
Ratede frequency / tolerance | 50/60 Hz ±2 (up to ±5 with generator - selectable) |
Environment |
| |
---|---|---|
Noise level at 1 m | < 51 dBA | < 54 dBA |
UPS cabinet |
|
---|---|
Type S - Dimensions W x D x H | 370 x 780 x 810 mm |
Type S - Weight (without batteries) | 58 kg |
Type M - Dimensions W x D x H | 370 x 780 x 1170 mm |
Type M - Weight (without batteries) | 75 kg |
Type T - Dimensions W x D x H | 370 x 780 x 1385 mm |
Type T - Weight (without batteries) | 82 kg |
Degree of protection | IP20 |
Standards |
|
---|---|
Safety | IEC/EN 62040-1, AS 62040.1.1, AS 62040.1.2 |
EMC | IEC/EN 62040-2 class C2, AS 62040.2 |
Performance | IEC/EN 62040-3 - AS 62040.3 |
Product certification | CE, RCM (E2376) |
Additional Information:
Product Details:
Power | 15 KVA TO 80 KVA |
Phase | Three Phase To Three Phase, Three Phase To Single Phase, Single Phase To Single Phase |
Input Voltage | 300 TO 500 |
Output Voltage | 415 |
Model Number | MASTERYSBC |
Cabinet type S height 800 mm Cabinet type M height 1000 mm Cabinet type T height 1400 mm |
Technical data
|
(1) The standard model is prepared for a 1+1 redundant system. Upon request, it is possible to have connected up to 6 modules in a parallel system.
(2) Conditions apply.
(3) Without batteries.
• Server rooms
• Service sector
• Infrastructure
• Healthcare sector
• Light industrial applications
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Brand | Microtek, Su-kam, Luminous, Hi-Tech,Any |
Capacity | <1 KVA |
Phase | Three Phase |
Input Voltage | 300 TO 500 |
Application | Commercial |
|
(1) The standard model is prepared for a 1+1 redundant system. Upon request, it is possible to have connected up to 6 modules in a parallel system.
(2) Conditions apply.
• Online double conversion mode with an output power factor of 0.9 providing 12% more active power compare to UPS with a power factor of 0.8.
• Dual input mains allows you to manage independent power sources.
• Increased system availability placing two UPS in parallel for 1+1 redundancy
• Internal manual bypass for easy maintenance without power interruption.
• Multilanguage display.
• Saves space with a reduced footprint and optimized cabinet size.
• Low noise level.
• Flexible battery solutions
•
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Power | 100 kva to 500 kva |
Phase | Three Phase To Three Phase, Three Phase To Single Phase |
Input Voltage | 300 to 500 |
Output Voltage | 415,400,380 |
• Server rooms
• Service sector
• Infrastructure
• Healthcare sector
• Light industrial applications
• Online double conversion mode with an output power factor of 0.9 providing 12% more active power compare to UPS with a power factor of 0.8.
• Dual input mains allows you to manage independent power sources.
• Increased system availability placing two UPS in parallel for 1+1 redundancy
• Internal manual bypass for easy maintenance without power interruption (1+1 configuration).
• Multilanguage display.
• Saves space with a reduced footprint and optimized cabinet size.
• Low noise level.
• Compact, lightweight and easy to install
• No neutral required on rectifier input.
• Two-wire battery connection (only +/-).
• Extende
|
(1) Conditions apply.
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Power | 15 KVA TO 80 KVA |
Phase | Three Phase To Three Phase, Three Phase To Single Phase |
Input Voltage | 400 V 3ph + N |
Output Voltage | 1ph + N: 230 V (can be configured 220/240 V) 3ph + N: 400 V (can be configured 380/415 V) |
• Server rooms
• Service sector
• Light industrial applications
• Online double conversion mode with an output power factor of 0.9 providing 12% more active power compare to UPS with a power factor of 0.8.
• Dual input mains allows you to manage independent power sources.
• Increased system availability placing two UPS in parallel for 1+1 redundancy
• Internal manual bypass for easy
Cabinet type S height 800 mm Cabinet type M height 1000 mm Cabinet type T height 1400 mm |
Technical data
|
(1) The standard model is prepared for a 1+1 redundant system. Upon request, it is possible to have connected up to 6 modules in a parallel system.
(2) Conditions apply.
(3) Without batteries.
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Input Voltage | 300 TO 500 |
Output Voltage | 400,415,380 |
Brand | APC, Any, Microtek, Su-kam, Luminous |
|
Additional Information: